SmartRay ECCO 95
SmartRay ECCO 95 : Telecamere HD per nuove applicazioni 3D
La famiglia dei sensori Ecco si allarga! I nuovi sensori SmartRay ECCO 95, ovvero la nuova frontiera per la misurazione 3D che combina alta risoluzione e velocità di misurazione.
Vantaggi
SmartRay ECCO 95
- Alta risoluzione – trovare i difetti più piccoli
- Maggiore precisione – Per una misura precisa
- Largo campo visivo – per scansionare oggetti più grandi
- Più punti 3D / sec – Per linee di produzione veloci
ECCO 95.010
Typical field of view (near | mid | far ) 1 | 10.5 | 11 | 11.5 mm |
---|---|
Measurement range 1 | 4 mm |
Stand-off distance | 23.5 mm |
Typical vertical resolution (Z) 1 | 0.37 – 0.45 µm |
Typical lateral resolution (Y) 1 | 5.8 – 6.8 µm |
Z-Linearity |
N/A |
Z-Repeatability |
N/A |
Weight | Approx. 650 g |
Part number | 3.002.152 (2M) | 3.003.152 (3B) |
Maximum points / 3D profile | 1920 |
---|---|
Typical scan rate 2 | Approx. from 400 Hz up to 8 kHz |
Typical 3D point rate 2 | Approx. from 0.7 up to 15 million points/sec |
Interface | Gigabit Ethernet ( 1 Gbit/ sec) |
Inputs | 4 x Inputs, 5 – 24 VDC Quadrature Encoder (AB-Channel, RS-422 Standard) |
Outputs | 2 x Outputs, 24 VDC (max. 20 mA) |
Trigger | START Trigger support on Input 1 – 2 DATA Trigger support on Quadrature Encoder Input (Max. DATA trigger rate: 1 MHz) DATA Trigger support on Input 2 (Max. DATA trigger rate: 10 kHz) |
Input voltage | Power | 24 VDC, ± 15 % ripple | 8.5 W |
Laser wavelength | 450 nm |
Laser class (standard | optional) | 2M|3R|3B |
Maximum ambient light | 10,000 lx |
EMC test | as per EN 61 000-6-2, EN 61 000-6-4 |
Vibration/ Shock test | as per EN 60 086-2-6, -27, -29, -64 |
Electrical safety | as per EN 61 010-1-3 |
Protection class | III, as per EN 61 040-3 |
Enclosure rating | IP65 |
Air humidity | Maximum 90%, non-condensing |
Temperature (operation | storage) | 0 – 40° C | -20 – 70° C |
Compatible accessories | Power-I/O-Encoder cable: 6.320.0XX Ethernet cable: 6.303.0XX |
Ecco 95.020
Typical field of view (near | mid | far ) 1 | 22 | 25 | 28 mm |
---|---|
Measurement range 1 | 20 mm |
Stand-off distance | 60 mm |
Typical vertical resolution (Z) 1 | 1.1 – 1.6 µm |
Typical lateral resolution (Y) 1 | 11.5 – 14.5 µm |
Z-Linearity 2,5 |
0.005% |
Z-Repeatability 4,5 |
0.2 µm |
Weight | Approx. 650 g |
Part number | 3.002.151 (2M) | 3.004.151 (3R) | 3.003.151 (3B) |
Maximum points / 3D profile | 1920 |
---|---|
Typical scan rate 3 | Approx. from 1 kHz up to 10 kHz (with full FOV) |
Typical 3D point rate 3 | Approx. from 0.7 up to 15 million points/sec |
Interface | Gigabit Ethernet ( 1 Gbit/ sec) |
Inputs | 2 x Inputs, 5 – 24 VDC Quadrature Encoder (AB-Channel, RS-422 Standard) |
Outputs | 2 x Outputs, 24 VDC (max. 20 mA) |
Trigger | START Trigger support on Input 1 – 2 DATA Trigger support on Quadrature Encoder Input (Max. DATA trigger rate: 1 MHz) DATA Trigger support on Input 2 (Max. DATA trigger rate: 10 kHz) |
Input voltage | Power | 24 VDC, ± 15 % ripple | 8.5 W |
Laser wavelength | 450 nm |
Laser class (standard | optional) | 2M|3R|3B |
Maximum ambient light | 10,000 lx |
EMC test | as per EN 61 000-6-2, EN 61 000-6-4 |
Vibration/ Shock test | as per EN 60 086-2-6, -27, -29, -64 |
Electrical safety | as per EN 61 010-1-3 |
Protection class | III, as per EN 61 040-3 |
Enclosure rating | IP65 |
Air humidity | Maximum 90%, non-condensing |
Temperature (operation | storage) | 0 – 40° C | -20 – 70° C |
Compatible accessories | Power-I/O-Encoder cable: 6.320.0XX Ethernet cable: 6.303.0XX |
ECCO 95.040
Typical field of view (near | mid | far ) 1 | 34 | 36 | 38 mm |
---|---|
Measurement range 1 | 16 mm |
Stand-off distance | 60 mm |
Typical vertical resolution (Z) 1 | 1.4 – 1.8 µm |
Typical lateral resolution (Y) 1 | 18 – 20 µm |
Z-Linearity |
N/A |
Z-Repeatability |
N/A |
Weight | Approx. 690 g |
Part number | 3.002.153 (laser class 2M) | 3.003.153 (laser class 3B) |
Maximum points / 3D profile | 1920 |
---|---|
Typical scan rate 2 | Approx. from 400 Hz up to 8 kHz |
Typical 3D point rate 2 | Approx. from 0.7 up to 15 million points/sec |
Interface | Gigabit Ethernet ( 1 Gbit/ sec) |
Inputs | 4 x Inputs, 5 – 24 VDC Quadrature Encoder (AB-Channel, RS-422 Standard) |
Outputs | 2 x Outputs, 24 VDC (max. 20 mA) |
Trigger | START Trigger support on Input 1 – 2 DATA Trigger support on Quadrature Encoder Input (Max. DATA trigger rate: 1 MHz) DATA Trigger support on Input 2 (Max. DATA trigger rate: 10 kHz) |
Input voltage | Power | 24 VDC, ± 15 % ripple | 8.5 W |
Laser wavelength | 450 nm |
Laser class (standard | optional) | 2M|3R|3B |
Maximum ambient light | 10,000 lx |
EMC test | as per EN 61 000-6-2, EN 61 000-6-4 |
Vibration/ Shock test | as per EN 60 086-2-6, -27, -29, -64 |
Electrical safety | as per EN 61 010-1-3 |
Protection class | III, as per EN 61 040-3 |
Enclosure rating | IP65 |
Air humidity | Maximum 90%, non-condensing |
Temperature (operation | storage) | 0 – 40° C | -20 – 70° C |
Compatible accessories | Power-I/O-Encoder cable: 6.320.0XX Ethernet cable: 6.303.0XX |
ECCO 95.100
Typical field of view (near | mid | far ) 1 | 72 | 98 | 124 mm |
---|---|
Measurement range 1 | 100 mm |
Stand-off distance | 150 mm |
Typical vertical resolution (Z) 1 | 5 – 12 µm |
Typical lateral resolution (Y) 1 | 42 – 70 µm |
Z-Linearity |
N/A |
Z-Repeatability |
N/A |
Weight | Approx. 490 g |
Part number | 3.002.150 (2M) | 3.003.150 (3B) |
Maximum points / 3D profile | 1920 |
---|---|
Typical scan rate 2 | Approx. from 400 Hz up to 8 kHz |
Typical 3D point rate 2 | Approx. from 0.7 up to 15 million points/sec |
Interface | Gigabit Ethernet ( 1 Gbit/ sec) |
Inputs | 4 x Inputs, 5 – 24 VDC Quadrature Encoder (AB-Channel, RS-422 Standard) |
Outputs | 2 x Outputs, 24 VDC (max. 20 mA) |
Trigger | START Trigger support on Input 1 – 2 DATA Trigger support on Quadrature Encoder Input (Max. DATA trigger rate: 1 MHz) DATA Trigger support on Input 2 (Max. DATA trigger rate: 10 kHz) |
Input voltage | Power | 24 VDC, ± 15 % ripple | 8.5 W |
Laser wavelength | 450 nm |
Laser class (standard | optional) | 2M|3R|3B |
Maximum ambient light | 10,000 lx |
EMC test | as per EN 61 000-6-2, EN 61 000-6-4 |
Vibration/ Shock test | as per EN 60 086-2-6, -27, -29, -64 |
Electrical safety | as per EN 61 010-1-3 |
Protection class | III, as per EN 61 040-3 |
Enclosure rating | IP65 |
Air humidity | Maximum 90%, non-condensing |
Temperature (operation | storage) | 0 – 40° C | -20 – 70° C |
Compatible accessories | Power-I/O-Encoder cable: 6.320.0XX Ethernet cable: 6.303.0XX |
Ecco 95.200
Typical field of view (near | mid | far ) 1 | 125| 190| 250mm |
---|---|
Measurement range 1 | 250 mm |
Stand-off distance | 325 mm |
Typical vertical resolution (Z) 1 | 12 – 50µm |
Typical lateral resolution (Y) 1 | 66 – 138µm |
Z-Linearity 2,5 |
0.015% |
Z-Repeatability 4,5 |
3.3 µm |
Weight | Approx. 490 g |
Part number | 3.006.154 (2M) | 3.008.154 (3R) | 3.007.154 (3B) |
Maximum points / 3D profile | 1920 |
---|---|
Typical scan rate 3 | Approx. from 1 kHz up to 10 kHz (with full FOV) |
Typical 3D point rate 3 | Approx. from 0.7 up to 15 million points/sec |
Interface | Gigabit Ethernet ( 1 Gbit/ sec) |
Inputs | 2 x Inputs, 5 – 24 VDC Quadrature Encoder (AB-Channel, RS-422 Standard) |
Outputs | 2 x Outputs, 24 VDC (max. 20 mA) |
Trigger | START Trigger support on Input 1 – 2 DATA Trigger support on Quadrature Encoder Input (Max. DATA trigger rate: 1 MHz) DATA Trigger support on Input 2 (Max. DATA trigger rate: 10 kHz) |
Input voltage | Power | 24 VDC, ± 15 % ripple | 8.5 W |
Laser wavelength | 450 nm |
Laser class (standard | optional) | 2M | 3R | 3B |
Maximum ambient light | 10,000 lx |
EMC test | as per EN 61 000-6-2, EN 61 000-6-4 |
Vibration/ Shock test | as per EN 60 086-2-6, -27, -29, -64 |
Electrical safety | as per EN 61 010-1-3 |
Protection class | III, as per EN 61 040-3 |
Enclosure rating | IP65 |
Air humidity | Maximum 90%, non-condensing |
Temperature (operation | storage) | 0 – 40° C | -20 – 70° C |
Compatible accessories | Power-I/O-Encoder cable: 6.320.0XX Ethernet cable: 6.303.0XX |